1, after the boot, but the screw with a screw at the exit of non-stop
The full stop sensor material transferred to the appropriate height; small circuit board with due emphasis on the strength of emission sensors;
No blocking gauge hook trigger sensor, adjust the position of the left and right trigger sensors;
Vibration to shake off the snap quickly lead screw too, can not stop the light, adjust the vibration to the right.
2, after the boot, no screw screw at the exit, but not vibration
Expected full stop sensor height adjustment is too low, the sensor is adjusted to the appropriate height;
The board is too weak emission sensors, appropriate transfer large emission intensity sensor.
3, the vibration motor is normal but is unstable or not to go feed screw
Are there foreign body stuck between the vibrating motor and chassis, ensure that the gap between the left side of the rail and the front plate in 0.5-1mm;
Ensure that the gap between the right and the striker plate with the guide rails in 0.5-1mm; check if any irregularities screw stuck, rail or screw if there is oil;
4, screw machine alarm
There are foreign body stuck to the screw machine moving parts or motor failure overload, short circuit board alarm.
5, the brush does not swing
Whether the slowdown in motor and transmission work; reset tension spring is off; rotating parts are flexible
6, the gauge can not block the screw hook
Check the gauge is off the hook shrapnel; check whether the loss of a small set of backgauge
7, two motor does not work
Check that the power cord is plugged in, the circuit board is faulty motor is normal; if there is vibration motor eccentric screw stuck.
8, rails easy card screw
Rail gap is larger than the screw diameter 0.1-0.3mm; whether the plate and screws to ensure that the gap in the range of about 0.3mm; brush height is appropriate, should be adjusted to just brush unsuccessful appropriate screws
9, rail routine maintenance
Every 15 daily alcohol to clean the inner side rail, the proposed use of rails per month degaussing degaussing
10, transmission parts maintenance
Every three months greasing
Contact: Winson Yang
Phone: 008619941451990
Tel: 008619941451990(WhatsApp)
Email:
Add: Zhenhai Zhuangshi street Xingzhuang Road No.9 Chuang e Huigu Building 42 Building B Room 408